Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output

Product Details
Customization: Available
After-sales Service: Free Repair
Warranty: 1 Year
Still deciding? Get samples of US$ 580/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
1001~2000 square meters
  • Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
  • Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
  • Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
  • Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
  • Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
  • Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
Find Similar Products

Basic Info.

Model NO.
MD-FM500
Accuracy
Na
Main Application
Water, Wastewater, Nature Gas
Size
Na
Sensor
Plug-in
Application
Industrial Production
Type
Electronic Flow Switch
Measuring Media
Gas
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Power
16~30VDC
Transport Package
Carton
Specification
0.5kg
Trademark
Meokon
Origin
Shanghai
Production Capacity
50000 PCS/Year

Product Description

Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output

Product Description:

The MD-FM500 gear flow sensor is built with double gears, which can calculate the volume of medium through the volume of high precision gear wheel and measure the fluid medium with small size. It is a new type of volumetric flow sensor, which is used to measure the flow or instantaneous flow of liquid in a pipe precisely continuously or intermittently. - analog switch double output -pnp /NPN switch arbitrarily -LED liquid crystal display - high pressure (1.0-45mpa) - high and low temperature resistance (-40ºC-150ºC) - various viscous media can be measured - high precision and repeatability - range specific width (1:100) - wide measurement range - strong anti-corrosion and anti-pollution ability (acid and alkali) arbitrary setting

Application:

The FM500 gear flow sensor is widely used in various 
industries for accurate measurement of low flow, suitable 
for media: additive fuel, water treatment flotation tank, 
corrosion inhibitors, catalysts, emulsifiers, oils, oils, 
spices, adhesives, solvents, inks and pesticides and other 
parts of high viscosity media. Application industries 
include automobile, aviation, mining, electric power, 
chemical, pharmaceutical, food, paint, petroleum, 
environmental protection, printing and other industries. . 
Particularly suitable for heavy oil. Polyvinyl alcohol 
resin, etc. The flow measurement of high viscosity medium. 
(can measure the viscosity is as high as 10000 pa. S fluid) 
small volume, light weight, runtime vibration noise and 
stable operation. Can also be used for measuring the small 
flow of small diameter measurement. Pick up small flow rate, 
range than wide, suitable for use in measuring conform to 
the changes of fluid flow, measuring accuracy is not 
affected by pressure and flow change, stable performance and 
long service life, large flow capacity.
- resin and glue measurement
- measurement of hydraulic oil, lubricating oil and grease
- fuel oil measurement
- ink and asphalt measurement
- measurement of liquid nitrogen, freezing liquid and 
solvent
- measurement of edible oil, fish oil and food filling
- fluid measurement for chemical and anticorrosion 
requirements
- fluid quantification control system

Technical Parameters: 
 Measuring range: 5-300mL/min,0.1-50L/min(customized range is supported)
 Output signals: 4-20ma,PNP/NPN
 Measurement accuracy: 0.5% f.s.
 Repeatability: 0.1% f.s.
 Power supply: 16~30VDC
 Medium temperature: -30~80ºC (high temperature customized 150ºC)
 Withstand pressure: aluminum (100bar), stainless steel(400bar), 
 PP (50bar)
 Material: shell: aluminum, stainless steel, display: stainless steel


DIEMENSION:
Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output



Manufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog OutputManufacturer′s High-Precision Gear Meter High-Pressure Resistant 45MPa Resin and Glue Measurement Pulse Output Analog Output
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier